- Heat source
- Kinetic energy of focused electrons
- Shielding
- Vacuum (or gas for non-vacuum EBW)
- Filler / consumables
- Usually none
- Power source
- EB gun (high voltage, typically 60–150 kV) and vacuum chamber
- Materials
- Steels, titanium, nickel superalloys, refractory and reactive metals, copper
- Thickness
- Foil to well over 100 mm in one pass
- Positions
- Any (part manipulated in the chamber)
- Deposition
- Not applicable
- Operation
- Automatic (CNC)