Tidak ada produk tercantum untuk kelas ini di referensi ini
Chosun Welding
Classification properties
Spesifikasi
AWS A5.17 / A5.23; ISO 14174
SI / metrik
e.g. F7A2-EM12K
Padanan ISO
ISO 14174: S A FB 1…
GB/T Tiongkok
SJ101 — flux class S A FB 1; GB/T 5293 S 43A 2 FB-SU26 / S 49A 4 FB-SU34 (≈ AWS A5.17 F6A0-EM12 / F7A4-EH14)
Pembungkus / jenis
Agglomerated or fused granular flux — acid, neutral or basic
Posisi
Datar dan las sudut horizontal
Arus
AC atau DC (tergantung fluks)
Kuat tarik
Equivalents come from the makers' catalogues and websites. Check your welding procedure before substituting.
F7: 70–95 ksi (480–660 MPa)
Kuat luluh
58 ksi (400 MPa)
Perpanjangan
22 %
Impak (CVN)
Set by the impact digit (e.g. 2 = 27 J at −29 °C)
Typical use
The flux sets slag behaviour, Mn/Si transfer and toughness. Its classification names the flux–wire pair: F = flux, 7 = 70 ksi, A = as-welded (P = PWHT), 2 = impact digit, EM12K = wire.
Basic fluxes give the best low-temperature toughness; active fluxes tolerate rust and suit single/two-pass work.