SJ101 — flux class S A FB 1; GB/T 5293 S 43A 2 FB-SU26 / S 49A 4 FB-SU34 (≈ AWS A5.17 F6A0-EM12 / F7A4-EH14)
کوٹنگ / قسم
Agglomerated or fused granular flux — acid, neutral or basic
پوزیشنز
مسطح اور افقی زاویائی ویلڈ
کرنٹ
AC یا DC (فلکس پر منحصر)
ٹینسائل اسٹرینتھ
Equivalents come from the makers' catalogues and websites. Check your welding procedure before substituting.
F7: 70–95 ksi (480–660 MPa)
ییلڈ اسٹرینتھ
58 ksi (400 MPa)
ایلونگیشن
22 %
امپیکٹ (CVN)
Set by the impact digit (e.g. 2 = 27 J at −29 °C)
Typical use
The flux sets slag behaviour, Mn/Si transfer and toughness. Its classification names the flux–wire pair: F = flux, 7 = 70 ksi, A = as-welded (P = PWHT), 2 = impact digit, EM12K = wire.
Basic fluxes give the best low-temperature toughness; active fluxes tolerate rust and suit single/two-pass work.